Lecture de smartctl
Le
Dominique
Bonjour,
Un smartctl -a /dev/sda
me renvoie :
*****************
START OF READ SMART DATA SECTION
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection:
Disabled.
Self-test execution status: ( 0) The previous self-test routine
completed
without error or no self-test
has ever
been run.
Total time to complete Offline
data collection: ( 440) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection
on/off support.
Suspend Offline collection upon
new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging
support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 046 Pre-fail
Always - 30071
2 Throughput_Performance 0x0005 100 100 030 Pre-fail
Offline - 19464192
3 Spin_Up_Time 0x0003 100 100 025 Pre-fail
Always - 1
4 Start_Stop_Count 0x0032 098 098 000 Old_age
Always - 6477
5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail
Always - 8589934592000
7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail
Always - 2772
8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail
Offline - 0
9 Power_On_Seconds 0x0032 075 075 000 Old_age
Always - 12988h+12m+18s
10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail
Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age
Always - 4257
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 90
193 Load_Cycle_Count 0x0032 094 094 000 Old_age Always
- 63166
194 Temperature_Celsius 0x0022 100 080 000 Old_age Always
- 49 (Lifetime Min/Max 15/64)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always
- 49
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 286064640
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age
Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always
- 11906
203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always
- 2632813379812
SMART Error Log Version: 1
No Errors Logged
**************************
J'ai un peu de mal à lire ces informations. Mon disque dur ne me semble
pas en souffrance malgré son grand âge. suis-je dans le vrai ?
Merci pour vos conseils et bonne journée,
--
Dominique
Courriel : dominique point sextant ate orange en France
Esto quod es
Un smartctl -a /dev/sda
me renvoie :
*****************
START OF READ SMART DATA SECTION
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection:
Disabled.
Self-test execution status: ( 0) The previous self-test routine
completed
without error or no self-test
has ever
been run.
Total time to complete Offline
data collection: ( 440) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection
on/off support.
Suspend Offline collection upon
new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging
support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 046 Pre-fail
Always - 30071
2 Throughput_Performance 0x0005 100 100 030 Pre-fail
Offline - 19464192
3 Spin_Up_Time 0x0003 100 100 025 Pre-fail
Always - 1
4 Start_Stop_Count 0x0032 098 098 000 Old_age
Always - 6477
5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail
Always - 8589934592000
7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail
Always - 2772
8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail
Offline - 0
9 Power_On_Seconds 0x0032 075 075 000 Old_age
Always - 12988h+12m+18s
10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail
Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age
Always - 4257
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 90
193 Load_Cycle_Count 0x0032 094 094 000 Old_age Always
- 63166
194 Temperature_Celsius 0x0022 100 080 000 Old_age Always
- 49 (Lifetime Min/Max 15/64)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always
- 49
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 286064640
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age
Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always
- 11906
203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always
- 2632813379812
SMART Error Log Version: 1
No Errors Logged
**************************
J'ai un peu de mal à lire ces informations. Mon disque dur ne me semble
pas en souffrance malgré son grand âge. suis-je dans le vrai ?
Merci pour vos conseils et bonne journée,
--
Dominique
Courriel : dominique point sextant ate orange en France
Esto quod es

Poser une question


À 2011-03-27T12:21:01+0200,
Dominique
Je pense que oui.
- SMART overall-health self-assessment test result: PASSED
- Pas de FAILING_NOW pour les valeurs WHEN_FAILED
- Et de plus, aucune erreur SMART enregistrée.
Yannick Palanque a écrit :
Par contre les valeurs brutes des attributs Reallocated_Sector_Ct et
Reallocated_Event_Count sont aberrantes.
Bonjour,
Je vous remercie d'avoir lu le compte-rendu de smartctl. Je suis heureux
de voir que mon vieux bousin de 7 ans révolus est encore en forme. Cela
dit, même avec Kubuntu 9.04, il a parfois un peu de mal mais je m'en
contente.
En quoi ces valeurs sont-elles aberrantes ?, Je ne sais pas les lire :
5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail Always
- 8589934592000
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 286064640
Bonne journée et merci encore,
--
Dominique
Courriel : dominique point sextant ate orange en France
Esto quod es
Ben... Il indique que 8589934592000 secteurs ont été réalloués.
Un disque dur de 1 To a 1953125000 secteurs ; le tien en a sans doute
moins.
À 2011-03-28T06:30:58+0200,
Dominique
Tu peux également lancer un test prolongé avec smartctl -t long /dev/sda
(par exemple).
Normalement il y a la section « SMART Self-test log structure revision
number 1 » après celle « SMART Error Log Version: 1 ».